Manufacturer Part# / Cross Reference Search
Please use this search function to find READY die set components that are equivalent to commonly used pins, bushing, ISO Springs, and Gas Springs from other manufacturers.
Please Note: We believe this cross reference to be accurate. Please review the specifications to ensure the item will work in your application. Gas Spring equivalents were based on body dimensions, on contact force and stroke length.
Ready recommends using only a premium grade of hydraulic oil.
The H-1 pump is available in six standard sizes. Each pump has four ports to activate up to four identical H-2 units. The quantity, size, and stroke length of the H-2 units hosed to each pump determines the size and oil volume of the pump needed. Pumps can be up to six feet away from H-2 units. This allows you to free up critical die space and balance die loads.
The H-1 pump is available in six standard sizes. Each pump has four ports to activate up to four identical H-2 units. The quantity, size, and stroke length of the H-2 units hosed to each pump determines the size and oil volume of the pump needed. Pumps can be up to six feet away from H-2 units. This allows you to free up critical die space and balance die loads.
Unit of Measure
Specifications
|
Note
|
Dimensions
|
Standard Features
|
Popular Options
|
Mounting Suggestions
|
Options
Specifications
Brands |
N/A HYDROCAM® Ready |
Metric Force |
N/A 7.8 ton |
Diameter (D1) |
N/A 40 mm1.575 in |
Diameter (D2) (x2) |
N/A 12 H7 mm |
Diameter (D3) (x2) |
N/A 16 mm |
Diameter (D4) |
N/A M30 x 2.0 |
Diameter (D5) |
N/A 26 mm1.024 in |
Diameter (D6) (x4) Metric Thread Size |
N/A M12 |
Piston Diameter (D7) |
N/A 50 mm1.969 in |
Nominal Head Punch Shank Diameter (D8) |
N/A 20 mm23 mm |
Diameter (G) British Standard Pipe Parallel Thread (BSPP) |
N/A G 3/8 |
De-Rated Force |
N/A 7094 daN15611 lbf |
VC Volume/Stroke (mm) |
N/A 1.963 cm³0.1198 in³ |
Maximum Force at 400 bar (5802 psi) Pressure |
N/A 7801 daN17200 lb |
Volume at 25 Millimeter (mm) Stroke |
N/A 49.09 cm³2.995 in³ |
Volume at 50 Millimeter (mm) Stroke |
N/A 98.17 cm³5.991 in³ |
Volume at 75 Millimeter (mm) Stroke |
N/A 147.26 cm³8.986 in³ |
Standard Minimum Return Force at 100 bar (1,450 psi) |
N/A 707 daN1589 lbf |
Maximum Return Force at 150 bar (2,175 psi) Pressure |
N/A 1061 daN2385 lbf |
Product Code |
N/A HC |
Note
Note |
N/A
De-rated Force equals maximum force less standard (minimum) return force. See H-2 dimension chart on previous page. All figures are nominal unless tolerance is stated. Forces are rated in metric tons (1 metric ton = 1.1 U.S. ton) |
Dimensions
Dimension (L1) at 25 Millimeter (mm) Stroke |
N/A 149 mm5.866 in |
Dimension (L1) at 50 Millimeter (mm) Stroke |
N/A 174 mm6.850 in |
Dimension (L1) at 75 Millimeter (mm) Stroke |
N/A 199 mm7.835 in |
Dimension (L2) |
N/A 12 mm0.472 in |
Dimension (L3) |
N/A 64 mm2.520 in |
Dimension (L4) |
N/A 48 mm1.890 in |
Dimension (L5) at 25 Millimeter (mm) Stroke |
N/A 138 mm5.433 in |
Dimension (L5) at 50 Millimeter (mm) Stroke |
N/A 163 mm6.417 in |
Dimension (L5) at 75 Millimeter (mm) Stroke |
N/A 188 mm7.402 in |
Dimension (L6) |
N/A 22 mm0.866 in |
Dimension (L7) |
N/A 12 mm0.472 in |
Dimension (L8) |
N/A 21 mm0.827 in |
Dimension (L9) |
N/A 9 mm0.354 in |
Dimension (B1) |
N/A 100 mm3.540 in |
Dimension (B2) |
N/A 76 mm2.992 in |
Dimension (B3) |
N/A 99 mm3.898 in |
Dimension (Ht 1) |
N/A 80 mm3.150 in |
Dimension (Ht 2) |
N/A 40 mm1.575 in |
Dimension (Ht 3) |
N/A 79 mm3.110 in |
Dimension (D9) Thread Size of Bolt |
N/A M16 |
Standard Features
Standard Features |
N/A
|
Popular Options
Popular Options |
N/A
|
Mounting Suggestions
Mounting Suggestions |
N/A
|
Options
Options |
N/A
Oil Return Option The oil return option can be an alternative to nitrogen, as a method of returning or retracting the H-2 unit. This option requires a hose from the H-2 unit to an external nitrogen/oil accumulator. The typical operating pressure of the forced oil return option is 100 bar (1450 psi). This option may require careful engineering analysis in order to calculate what is best for a customer’s application. READY can assist in this evaluation. User Sequence Option This option requires careful application engineering to determine feasibility. Engineering fees may apply. User sequence can allow customers to control the timing of their HYDROCAM® Systems. The H-2 unit can be programmed to extend, dwell, and retract at nearly any point in the stroke. This allows for multiple actions to be performed in a single operation. Contact Ready for the latest developments on this exciting HYDROCAM® system technology. Direct Punch Option This option is used when piercing round holes only. A metric punch of the proper size range can be used. The punch shank size is limited, and is listed on the bottom of the H-2 selection chart. By removing the standard front plate, the H-2 piston will accept a customer supplied head type punch. A special locking nut is included with this option. The direct punch option fits compact areas. |