Ready recommends using only a premium grade of hydraulic oil.

The H-1 pump is available in six standard sizes. Each pump has four ports to activate up to four identical H-2 units. The quantity, size, and stroke length of the H-2 units hosed to each pump determines the size and oil volume of the pump needed. Pumps can be up to six feet away from H-2 units. This allows you to free up critical die space and balance die loads.
Unit of Measure

Specifications

Brands

N/A HYDROCAM® Ready

Total Volume (VT)

N/A 400 cm³24.409 in³

Total Volume (Volume/Stroke Per mm)

N/A 13.273 cm³20.5735 in³

Die Open Height (Ht 1)

N/A 195 mm7.677 in

Height of Base (Ht 2)

N/A 50 mm1.969 in

Maximum Volume Stroke (Ht 4)

N/A 30 mm1.181 in

Approach Stroke (Ht 5)

N/A 8 mm0.315 in

Piston Diameter (D1)

N/A 130 mm5.118 in

Rod Diameter (D2)

N/A 60 mm2.362 in

Body Diameter (D3)

N/A 182 mm7.165 in

Minimum Diameter (D4) (Not Supplied)

N/A 120 mm4.724 in

Minimum Base Cross Corners Diameter (D5)

N/A 246 mm9.685 in

Minimum Optional Gauge Diameter (D6)

N/A 180 mm7.087 in

Base Square 1

N/A 185 mm7.283 in

Bolt Hole Pattern Square 2

N/A 150 mm5.906 in

Piston Area (P)

N/A 132.73 cm²20.574 in²

Piston Rod Travel

N/A Piston rod travel controls oil volume going to the H-2 unit(s).

Optional Stroke Gauge Ring

N/A Used as a visual gauge to assist in set-up. Ring is located on top of pump body and made to the appropriate height based upon piston rod travel calculation. This stroke gauge ring is not a stop block and should be used for set-up purposes only.

Total Stroke (Ht3)

N/A 38 mm1.496 in

Product Code

N/A HC

Dimensions

Dimension (M) (x4)

N/A M16

Dimension (G) (x4) British Standard Pipe Parallel Thread (BSPP) Size

N/A G-3/8

Mounting Suggestions

Mounting Suggestions

N/A
  • The H-1 pump's piston rod must be up and perpendicular to the ram.
  • H-1 pump must be located at or above the H-2 unit's elevation.
  • Locate the H-1 anywhere in the die under the ram that provides ram balance and simple hose access to the H-2 unit(s).
  • Locate the H-1 pump within six feet of the H-2 unit(s).
  • Always use stop blocks.
  • Die storage blocks are recommended.
  • Never store pump with piston rod depressed or upside down.

Options

Options

N/A Oil Return Option

The oil return option can be an alternative to nitrogen, as a method of returning or retracting the H-2 unit. This option requires a hose from the H-2 unit to an external nitrogen/oil accumulator. The typical operating pressure of the forced oil return option is 100 bar (1450 psi). This option may require careful engineering analysis in order to calculate what is best for a customer’s application. READY can assist in this evaluation.

User Sequence Option

This option requires careful application engineering to determine feasibility. Engineering fees may apply. User sequence can allow customers to control the timing of their

HYDROCAM® Systems.

The H-2 unit can be programmed to extend, dwell, and retract at nearly any point in the stroke. This allows for multiple actions to be performed in a single operation. Contact Ready for the latest developments on this exciting HYDROCAM® system technology.

Direct Punch Option

This option is used when piercing round holes only. A metric punch of the proper size range can be used. The punch shank size is limited, and is listed on the bottom of the H-2 selection chart. By removing the standard front plate, the H-2 piston will accept a customer supplied head type punch. A special locking nut is included with this option. The direct punch option fits compact areas.