Drilled diameters larger than 126 mm should be capped with a plate and "O" rings. The number, grade, and preload of the screws must be specified for a pressure of 165 bars (the maximum pressure of the safety plugs), a safety factor of 1.5, and a cyclic fatigue loading.
Unit of Measure
Specifications
Brands |
N/A Ready |
Features |
N/A Port |
Diameter D |
N/A 145 mm |
Diameter d |
N/A 8.1 mm |
Thread Size P |
N/A M 130 x 2 |
O-Ring Diameter (D x S) |
N/A 126 x 4 mm |
For Maximum Drilled Diameter |
N/A 126 mm |